Inner Surface Reference
11.2.1.13 - The inner surfaces of the smoke chamber shall be parge coated smooth, with an insulating refractory mortar, and not inclined more than 45 degrees from vertical.
Depth Reference
11.2.1.12 - The smoke chamber depth shall not be greater than the depth of the fireplace chamber.
Height Reference
11.2.1.11 - The smoke chamber height shall not be greater than the inside width of the fireplace room opening.
Thickness Reference
11.2.1.10 - Where unlined, the smoke chamber wall thickness shall not be less than 8"
Cross Section Reference
11.2.1.3.3 - The cross sectional area of the passageway above the firebox including the throat, damper, and smoke chamber shall not be less than the cross sectional area of the flue